| Model | EMS61000-12C |
| Peak Pulse Voltage (Open Circuit) | 0.25kV~7.0kV,tolerance:±10% |
| Oscillation Frequency | 100kHz,tolerance:±10% |
| Voltage Rise Time (First Peak) | 0.5µs,tolerance:±30% |
| Current Rise Time (First Peak) | ≤1µs |
| Voltage Decay | 0.4<Pk2/Pk1<0.9 0.4<Pk3/Pk2<0.8 0.4<Pk4/Pk3<0.8 No requirement for other peaks |
| Output Impedance | 12Ω、30Ω |
| Polarity | Positive / Negative / Positive-Negative / Negative-Positive |
| Pulse Interval | 1s~9999s |
| Number of Pulses | 1~9999 |
| Trigger Phase | Asynchronous / Phase-synchronized / External synchronization (0° to 359°) |
| Trigger Mode | Manual/Auto/External |
| Built-in Single/Three-phase CDN | MAX Line Voltage 440VAC/20A,DC 300VDC/20A |