Home Products Flicker&Glare Test START-1000 Start/run up Time Test System
START-1000 Start/run up Time Test System
High Sampling according to International Standard
Typical application scenarios
Start-1000 can be used to record the start rise time and waveform of the light source in real time, and according to the design requirements of the EU directive 1194/2012, Energy Star and the international standard IEC60969, etc., it is specially used for LED lights, lamps and energy-saving lamps. And it can also be used to measure the photometry parameters of stable light sources.
Everfine
Main characteristics
1. It integrates high precision and fast storage of photometric measurement, synchronous triggering of voltage zero crossing and touch screen display, and automatically obtains the start/rise time of light source through data analysis.
2. Precision photometric detector: CIE CLASS A, luminous flux measurement range: 0.1 lm~200 klm (related to the size of the supporting integrating sphere).
Everfine
3. Trigger terminal voltage output stability: ≤0.2%, trigger terminal voltage total distortion THD: ≤0.5%.
Technical Specifications